Sustainable
Particularly simple maintenance access. Maintenance work in cleanrooms is particularly time consuming and cost intensive due to the elevated hygiene requirements. Fidesca G3 LED is prepared for this twice over. Firstly, with a long service life of 90,000 h (L80), and secondly, with easy maintenance access. If maintenance is required, the luminaire’s light engine can be replaced. No luminaire replacement, no interventions in the building structure.
90,000 h
Sustainable
Particularly simple maintenance access. Maintenance work in cleanrooms is particularly time consuming and cost intensive due to the elevated hygiene requirements. Fidesca G3 LED is prepared for this twice over. Firstly, with a long service life of 90,000 h (L80), and secondly, with easy maintenance access. If maintenance is required, the luminaire’s light engine can be replaced. No luminaire replacement, no interventions in the building structure.
90,000 h
Certified
Safely meeting maximum hygiene standards. Fidesca G3 LED is available with various power levels for all standard hygiene requirements in cleanrooms. The luminaire has been certified for ISO class 1 and fulfils the requirements of the GMP guideline. The easy-to-clean cover made of laminated safety glass prevents glass splinters from falling in case of damage. In addition, the frame protects the luminaire from unnoticed damage during installation.
ISO class 1
Certified
Safely meeting maximum hygiene standards. Fidesca G3 LED is available with various power levels for all standard hygiene requirements in cleanrooms. The luminaire has been certified for ISO class 1 and fulfils the requirements of the GMP guideline. The easy-to-clean cover made of laminated safety glass prevents glass splinters from falling in case of damage. In addition, the frame protects the luminaire from unnoticed damage during installation.
ISO class 1
- Suitable for all cleanrooms: Certified according to Fraunhofer Institute to meet the hygiene requirements of ISO class 1
- Large range variety: Maximum flexibility thanks to a wide range of versions in terms of lighting technology, sizes, protection ratings, etc.
- Uniform design: A uniform design concept for all versions facilitates solutions across applications
- Excellent light: Excellent lighting technology for highest quality demands, e.g. UGR19 and Ra > 90
Lighting design
The wide selection of protection ratings, sizes, light distribution characteristics and luminous flux packages means that all rooms with high hygiene requirements can be perfectly illuminated. Especially convenient: The versions are designed for a 1:1 refurbishment of conventional systems.
Design
Sophisticated design from a single cast: A uniform design identifies all versions of Fidesca G3 LED as part of one luminaire range. This facilitates cross-application solutions in a holistic design. The frame is a central, functional element – it is easy to clean and protects the luminaire against unnoticed damage during installation.
FIDESCA PM G3 LED | FIDESCA SD G3 LED | Fidesca BS G3 LED | |
Lumen packages | 6,900 lm, 8,600 lm, 10,300 lm, 12,400 lm | 5,500 lm, 6,900 lm, 7,500 lm, 8,500 lm, 13,000 lm, 20,000 lm | 3,000 lm, 5,500 lm, 7,500 lm |
Efficiency | 105 to 120 lm/W | 135 to 150 lm/W | up to 150 lm/W |
Service life |
90,000 h at L80 tq 40°C, 70,000 h at L85 tq 25°C |
90,000 h at L80 tq 40°C, 70,000 h at L85 tq 25°C |
90,000 h at L80 tq 40°C, 70,000 h at L85 tq 25°C |
Ambient temperature | -20° to +40°C | -20° to +40°C | -20° to +40°C |
Protection rating | IP 65 | IP 65, IP 65 room side/IP 54 ceiling side | IP 54 |
ISO class | 1 | 1 | / |
Impact resistance | IK 08 | IK 08 | IK 04 |
HACCP, IFS, BRC compliant | yes | yes | yes |
Approval marks | CE, D, ENEC | CE, D, ENEC | CE, D, ENEC |
Light engine replaceable | yes | yes | / |
Housing material | Sheet steel, laminated safety glass (VSG) | Sheet steel, laminated safety glass (VSG) | Sheet steel, PMMA |
Optics | Wide distribution, asymmetric wide distribution | Wide distribution, Lambertian, narrow distribution | Wide distribution, Lambertian |
Glare reduction | UGR <19 | UGR <19, UGR <22, UGR <25 | UGR <19, UGR <22 |
Colour rendering/temperature | CRI 90 (TLCI > 80), 4.000 K | CRI 80 (TLCI > 60), CRI 90 (TLCI > 80), 4.000 K, 6.500 K, Tunable White | CRI 80 (TLCI > 60), 3.000 K, 4.000 K |
Electrical version | ETDD (DALI dimmable) | ETDD (DALI dimmable) | ETDD (DALI dimmable) |
Installation methods | Surface-mounting, recessing (with accessories) | Surface-mounting, recessing | Recessing |
Construction sizes | 300x1250 (D1), 300x1550 (D2), 412x1250 (D3), 412x1550 (D4) | 600x600 (M73), 625x625 (M84), 300x1200 (M46), 312x1250 (M57), 625x625 (D), 300x1250 (D1), 412x1550 (D4) | 600x600 (M73), 625x625 (M84), 300x1200 (M46), 312x1250 (M57) |
Areas of application | Operating theatres, Specialist laboratories |
Healthcare: OR periphery, intensive care, laboratories, examination rooms Industry: Food, microelectronics, cleanrooms in aerospace technology |
Healthcare: Laboratories, examination rooms, patient rooms, functional rooms Industry: Pharmaceuticals, food, microelectronics, industrial kitchens, laundries |
LiveLink-ready | yes | yes | yes |
LiveLink integrated | - | yes | yes |
LiveLink Wireless (radio) | - | - | - |
CLO-ready | yes | yes | yes |
MOR (monitoring-ready) | yes | yes | yes |